Audison LR 435 Owner's Manual Page 9

  • Download
  • Add to my manuals
  • Print
  • Page
    / 12
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 8
9
CONTROLS PANEL
LO-PASS
It permits to activate (On) or bypass
(Bypass) the LO-PASS filter. In this way,
a Lo-Pass signal or a full range one will
be on the output, that is selected by
AMP: HI/LO-PASS switch.
9
HI-PASS
It permits to activate (On) or bypass
(Bypass) the HI-PASS filter. In this way,
a Hi-Pass signal or a full range one will
be on the output, that is selected by
AMP: HI/LO-PASS switch.
8
MODE
It permits to switch the amplifier
functioning mode between Stereo and
Mono (bridged).
4
F1
It permits to set Lo-Pass and Hi-Pass
crossover point between 40 and 500 Hz.
6
LEVELS
It adjusts the input sensitivity of both
amplifier channels and sets their output
level.
5
SAFETY (red LED)
It indicates that the amplifier protection
circuits are on. In order for the amplifier
to work again, you need to switch the
system off and then on after 10 seconds
at least. We recommend to check all
connections before switching the
amplifier on again.
If LED stays on, please contact Audison
authorised after sale centres.
10
RANGE: x1/x10
Frequencies range switch.
It permits to select the preset frequencies
ranges within which to realise the
crossover point between Lo-Pass and
Hi-Pass through F1.
x1 40 ÷ 500Hz
x10
400Hz ÷ 5kHz
7
12
16
16
CONFIGURATION EXAMPLES
MONO (FRONT+SUB)
Page view 8
1 2 3 4 5 6 7 8 9 10 11 12

Comments to this Manuals